{rfName}
Pa

Indexat a

Altmetrics

Anàlisi d'autories institucional

Unzue, LAutor o coautor

Compartir

5 desetembre de 2022
Publicacions
>
Review
No

Paravalvular leaks: mechanisms, diagnosis and management

Publicat a: EuroIntervention. 8 Q41-Q52 - 2012-09-01 8(), DOI: 10.4244/EIJV8SQA9

Autors:

Garcia, Eulogio; Sandoval, Jorge; Unzue, Leire; Hernandez-Antolin, Rosana; Almeria, Carlos; Macaya, Carlos
[+]

Afiliacions

San Carlos Univ Hosp, Dept Cardiac, Cardiovasc Inst, Madrid, Spain - Autor o coautor

Resum

Aims: To understand the incidence, aetiology and mechanisms of paravalvular aortic and mitral leaks after valvular surgery; reviewing the best methods for diagnosis, procedural guidance and result assessment of these leaks, as well as describing the different approaches to their treatment.Methods and results: A literature search was undertaken as well as an in-depth analysis of our own experience concerning different imaging modalities and various therapeutic strategies for aortic and mitral paravalvular leaks. The majority of patients were diagnosed using two- or three-dimensional transoesophageal echocardiography, useful in both guiding the procedure as well as assessing the procedural results. Haemoglobin, haematocrit, LDH and haptoglobin values were analysed to assess haemolysis. Procedural success for percutaneous closure of paravalvular aortic leaks are around 90% in the different series, with low complication rates. Mitral leaks have been approached by transfemoral and transapical access; the reported success of this procedure ranges from 75% to more than 90% in different reports. Complication rates at 30 days average 10% and mortality related to the procedure is around 1%. Late follow-up results depend on the initial anatomy, baseline clinical class and procedure results.Conclusions: Paravalvular leaks after surgical valve implantation have a multifactorial aetiology, but are mainly related to specific anatomic characteristics of the valvular ring. Mitral leaks are three times more common than aortic leaks and the incidence increases after reoperation. Different percutaneous techniques with several devices have been explored for leak closure, but we are still lacking devices specifically designed to treat this pathology more effectively.
[+]

Paraules clau

3-dimensional transesophageal echocardiographyAmplatzer vascular plugAortic-valve-replacementFollow-upImpingementMitral regurgitationParavalvular leakPercutaneous closurePercutaneous interventionPeriprosthetic leaksProsthetic regurgitationReoperationRepairTranscatheter closure

Indicis de qualitat

Impacte bibliomètric. Anàlisi de la contribució i canal de difusió

El treball ha estat publicat a la revista EuroIntervention a causa de la seva progressió i el bon impacte que ha aconseguit en els últims anys, segons l'agència Scopus (SJR), s'ha convertit en una referència en el seu camp. A l'any de publicació del treball, 2012, es trobava a la posició , aconseguint així situar-se com a revista Q1 (Primer Cuartil), en la categoria Medicine (Miscellaneous). Destacable, igualment, el fet que la revista està posicionada per sobre del Percentil 90.

Independentment de l'impacte esperat determinat pel canal de difusió, és important destacar l'impacte real observat de la pròpia aportació.

Segons les diferents agències d'indexació, el nombre de citacions acumulades per aquesta publicació fins a la data 2026-04-05:

  • WoS: 24
  • Europe PMC: 13
[+]

Impacte i visibilitat social

Des de la dimensió d'influència o adopció social, i prenent com a base les mètriques associades a les mencions i interaccions proporcionades per agències especialitzades en el càlcul de les denominades "Mètriques Alternatives o Socials", podem destacar a data 2026-04-05:

  • L'ús d'aquesta aportació en marcadors, bifurcacions de codi, afegits a llistes de favorits per a una lectura recurrent, així com visualitzacions generals, indica que algú està fent servir la publicació com a base del seu treball actual. Això pot ser un indicador destacat de futures cites més formals i acadèmiques. Aquesta afirmació està avalada pel resultat de l'indicador "Capture", que aporta un total de: 42 (PlumX).
[+]